Thursday, September 29, 2016

Advice on Patch Cable Selection for Optical Transceiver

Fiber optic network connection can’t be achieved without fiber optic transceivers and fiber patch cables. Fiber optic transceivers vary from transmission media, interface, transmission distance, data rate, and brand, for example, SFP for 1000Mbps, SFP+ for 10G, QSFP+ for 40G, CFP and QSFP28 for 100G. It’s not difficult to identify these transceivers. But when you connect the transceiver to the patch cable, many details need to be noticed. This article will give you advice on how to choose the suitable patch cable for your transceivers.
Transmission Media—Copper & Fiber
According to transmission media of fiber optic and copper, transceivers can be divided into two kinds, copper based transceivers and fiber optic based transceivers. MSA has defined several copper based transceiver like: 100BASE-T, 1000BASE-T and 10GBASE-T. Copper transceivers are available in GBIC, SFP and SFP+ form factors, which usually has a RJ45 interface. So Cat5/6/7 cables are typically used to connect with the transceivers. Maybe Cat8 will be researched and developed to support higher data rate up to 40G sooner or later.


As to fiber optic transceivers, things are more complex. For that fiber optic transceivers require different fiber patch cords which have more types. Fiber patch cables cover single-mode and multimode. Single-mode patch cable can be classified into OS1 and OS2. While multimode cables can be divided into OM1, OM2, OM3, OM4 cable. Different cables are used in different applications. Single-mode cable can support long distance transmission and multimode cable for short distance link. If the transmission distance is shorter than 500 meters, multimode patch cable is suggested. For long distance transmission, single-mode transmission is suggested. You should also consider that the transmission data rate can also affect the transmission distance. Let’s look at the following point.

Supported Distance and Data Rate
MSA has defined a variety of transceivers that can support different transmission distances and data rates. When you buy a fiber optic transceiver, you will find the data rate, wavelength, distance, etc. on its labeling. The following table show the basic information of most often used transceivers and supported cable type.
DescriptionWavelenghData RateCable TypeDistance
SX850nm1GMM500 m
LX1310nm1GSM8 km
EX1310nm1GSM40 km
ZX1550nm1GSM70 km
SR850nm10GMM300 m
LR1310nm10GSM10 km
ER1550nm10GSM40 km
ZR1550nm10GSM80 km
SR4850nm40GMM100 m
SR10850nm100GMM100 m
LR41310nm40GSM10 km
As mentioned before, single-mode patch cable is better for long distance transmission and multimode patch cable for short distance transmission. Actually single-mode patch cords can be used for different data rates in both long and short distances. But single-mode fiber optic cable will cost more. To achieve reliable performance in short distances with cost effective solutions, you should know the performance of multimode fiber optic cables. The following chart provides the detailed transmission distances and data rates information for different multimode fiber optic cables over wavelength of 850 nm for your reference.
Fiber Type1G10G40/100G
OM1300 m36 mN/A
OM2500 m86 mN/A
OM31 km300 m100 m
OM41 km550 m150 m
Transceiver Interfaces
The selection of patch cable for transceiver should also consider the interfaces through which patch cords is connected to the transceiver. In addition, transceiver usually used one port for transmitting and one port for receiving. Generally, fiber optic transceivers usually employs duplex SC or LC interfaces. However, for BiDi transceivers only one port is used for both transmitting and receiving. Thus, simplex patch cord is used with BiDi transceiver.
Some 40G/100GBASE QSFP+ transceivers used MTP/MPO interfaces, which should be connected to the network with multi-fiber patch cords attached with MTP/MPO connectors. If these ports are used for 40G to 10G or 100G to 10G connection, then fanout patch cable should be used. For example, a MTP to 8 LC fanout cable can splitter 40G data rate to four 10G data rate.
Summary
Next time when you select patch cords for your fiber optic transceivers, you can consider these factors like transmission media, transmission data rate and distance, transceiver interfaces. FS.COM offers a wide range of fiber optic transceivers and patch cords. Custom service is also available. Any problem, please contact us via sales@fs.com.
Originally published at www.fiber-optic-equipment.com

Tuesday, September 20, 2016

How to Make Your Own Ethernet Cables?

Ethernet patch cables are indispensable for network. However, Ethernet patch cables are more expensive than bulk cables and the pre-terminated lengths are not always that you need. So it’s quite necessary to know how to wire Ethernet cable by yourself. This article will show you detailed steps of making your own Ethernet patch cable.
Materials You Need

Bulk Ethernet cable
Usually people will choose Cat5e cable. Cat5e cable is a little different from Cat5. It can handle data rate up to 1000Mbps. Cat5e is suitable for Gigabit Ethernet and experiences much lower levels of near-end crosstalk (NEXT) than Cat5. So in most applications, Cat5 has been superseded by Cat5e. Except Cat5e, you may also choose Cat6 cables which have better performance. Cat6 cable has twice the bandwidth of Cat5. It’s ideal for supporting 10 Gigabit Ethernet. Select the cable type and then buy the lengths of the cable you need.
RJ45 Connectors for Cat5e or for Cat6
RJ45 connectors are often used for telephone and network. RJ45 connectors include a variety of types for Cat 5e or Cat6, such as shielded, strain relief boots, 2 prong or 3 prong, etc. Whatever, you need to select the one suitable for your application. FS.COM provides plenty of RJ45 connectors meeting a high standard of safety quality.

RJ-45 Crimping Tool
RJ45 crimping tool is designed to quickly, strip, crimp and cut the wires in an easy operation. FS.COM supplies various types of high quality crimping tools. With this kind of tool, you can get precise and reliable terminations every time.
Steps for Wiring Ethernet Cable
Step 1. Strip Outer Sheath
Use your stripper on your crimping tool to strip 1 inch (2.5 cm) sheath from the end of the cable. Insert the cable into the stripper portion of the crimping tool and squeeze it tight. When squeezed, rotate the crimping tool around the cable a full 360°. At last, pull away and the sheath will be stripped. If you break the internal twisted wires by accident, just cut the broken wire and strip again. So when you measure the cable length, you should better leave spare inches in case things happen like this.
Step 2. Untwist and Arrange Wire
After stripping the sheath, you can find 8 color-coded wires inside. Then you need to untwist the internal wires and arrange them into a proper wiring scheme for RJ45 connector. There are two kinds of color codes standards: T568A and T568B. The color order is important to get correct. No matter which standards you choose, you should arrange the color-coded wires in the same order on both sides. Here recommend you T568B color-coded wiring. The following are about pins and colors used in T568B standards.
Pin1—White/Orange
Pin2—Orange
Pin3—White/Green
Pin4—Blue.
Pin5—White/Blue
Pin6—Green.
Pin7—White/Brown
Pin8—Brown
Step 3. Insert the wire into RJ45 connector
Before insert the wire into RJ45 connector, you need to cut down the wire to fit in the connector. Bring the wires together and cut them down in an even line with the cutting tool on the crimping tool. Then insert the wires into the connector in the right order. Ensure each wire fits into each groove in the connector. The wires should be inserted until the sheathing is inside the connector, just beyond the crimp portion of the connector.
Step 4. Crimp
Put the connector into the crimping tool carefully until the connector can’t go in any further. Squeeze the crimping tool very tightly and release. Then squeeze the the crimping tool again to make sure that all of the pins are pushed down on the connector. When finishing crimping, check that if all pins are all crimped down. If the pins are all down, tug the connector slightly to make sure that it is securely attached to the wire.
Step 5. Test
Before installing the cable, you should better take a test with an Ethernet cable tester. If the Ethernet cable doesn't work, look closely at each end and see if you can find the problem. Usually the problem is caused because a wire ends up in the wrong place or one of the wires makes no contact or poor contact. You should also check if the color is in the right order. If the color order is wrong, then cut the end off and start again.
Summary
Sure, you can buy Ethernet cables from the store directly. But if you need to make your own cable with special lengths, then you are lucky to read this article. Remember that the Ethernet cable should be no more than 100 meters or 328 feet. Because the cable performance will be influenced by the over length. For bulk cables, RJ45 connectors, crimping tools, and network testers, etc., you can get all from FS.COM. Hope you can make your own Ethernet cable successfully.
Originally published at www.fiber-optic-equipment.com

Tuesday, September 13, 2016

How to Distinguish T568A and T568B of RJ45 Ethernet Cable Wiring?

Ethernet cable can be easily found in our daily life. Ethernet cable is color-coded if you look at it carefully. Color-coded wiring sequences exist as a cabling industry standard. Thus, cabling technicians can save a lot of time of doing cable termination on both ends by following others’ work without guessing or deciphering the function and connections of each wire pair. This article will tell the T568A and T568B standards that the Ethernet cable jack wiring follows.
What Are T568A and T568B standards?
RJ45 conductor data cable contains 4 pairs of wires. Each one consists of a solid colored wire and a strip of the same color. There are two wiring standards for RJ45 wiring: T568A and T568B. T568A and T568B are the two wiring standards for RJ45 connector data cable. T568A was specified by TIA/EIA-568-A wiring standards in 1995. Later it was replaced by the TIA/EIA 568-B standard in 2002 and has been updated since. Both standards define the T568A and T568B pin-outs for using unshielded twisted pair cable and RJ45 connectors for Ethernet connectivity. These two standards and pin-out specification appear to be related and interchangeable. But they still have differences and should not be used interchangeably.

RJ45 Color-Coded Scheme
RJ45 cables have 8 color-coded wires and the plugs have 8 pins and conductors. Eight wires are used as 4 pairs, each representing positive and negative polarity. The following figure shows pin and colors used in the T568A and T568B standards.

Straight-through and Cross-over Connections
The wiring standards T568A and T568B are used to create a cross-over cable (T568A on one end, and T568B on the other end), or a straight-through cable (T568B or T568A on both ends).
Straight-through cables are used to connect computers to a Ethernet switch. The RJ45 cable uses only 2-pairs of wires: orange (pins 1, 2) and green (pins 3, 6). Pins 4, 5 (blue) and 7, 8 (brown) are not used. Straight-through cable connects pin 1 to pin 1, pin 2 to pin 2, pin 3 to pin 3, and pin 6 to pin 6.

Cross-over cable is used to network two computers without a Ethernet switch (hub). Cross-over cable connects pin 1 to pin 3, pin 2 to pin 6, pin 3 to pin 1 and pin 6 to pin 2. This kind of cable is used to connect TX+ (transmit) to RX+ (receive), and TX- to RX-. The unused pins are generally connected straight-through in both straight-through and cross-over cables.

Which Standard Should You Choose?
Actually there is no electrical difference between the T568A and T568B wire sequences. So it’s hard to tell which one is inherently better. The difference between the two is the position of the orange and green wire pairs. It is preferable to wire to T568B standards if there is no pre-existing pattern used within a building.
In fact, both standards are acceptable in most cases. You can use either one as long as you're consistent. T568B is the standard followed by the majority of Ethernet installations in the United States for RJ45 color code. It is the more common standard used when cabling for businesses. While T568A is the majority standard followed by European and Pacific countries. It is also used in all United States government installations. So when you face the selection, you may make the decision on the country you work in and what types of organizations you install for.
Conclusion
T568A and T568B are the two wiring standards for RJ45 connector data cable specified by TIA/EIA-568-A wiring standards document. Color-coding is part of the standards. If modifying the Ethernet cables improperly, signal loss of network connectivity can be caused. So please insure all connectors and cables are modified in accordance with standards when you do cable terminations.
Originally published at www.fiber-optic-equipment.com

Friday, September 9, 2016

Secrets of Choosing Fiber Rack Mount Enclosure

Fiber rack mount enclosures can provide a high-density solution for inter-connects or cross-connects between backbone horizontal cable and active equipment. Enclosures allow for easy field termination of connectors or installation of pre-terminated solutions, and are ideal for high-density fiber applications in data centers, equipment rooms, and central offices. Fiber rack mount enclosures come in different configurations. You may find fiber enclosures in the market with different sizes, slide-out or lid type, fixed front panel or removable front panel, splice tray or preterminated. Among so many types, you have to choose one that suits your application the most. So how to make the right decision? The following will tell you the method.

Which Size of Rack Mount Enclosure?
The rack mount units are designed for rack mounting in 19-in (48 cm) racks. They are available in rack space options of 1U (two panels, cassettes or modules), 2U (four panels, cassettes or modules), 3U (six panels, cassettes or modules) and 4U (twelve panels, cassettes or modules), etc.(See the following picture.) You should choose the most proper one depending on the space and port requirement of your project.

Slide-out Type or Lid Type?
The rack mount enclosures include two kinds. One is the slide-out type, and the other incorporates a removable lid. The slide out type is more expensive while the lid type is less expensive but requires the user to remove the whole enclosure from the rack to gain internal access. If your budget is sufficient, I will recommend you to use the slide-out type. Then you may get more benefits during installation and maintenance, as they respectively feature a convenient slide-out support tray and a integrated swing-out tray so that you don’t need to remove the whole enclosure from the rack to gain internal access.
Fixed Front Panels or Removable Front Panels?
As we know, fiber optic adapters are the key part of an enclosure to accept the various fiber optic connectors. Thus, to choose a proper front panel option is also important. For general rack mount enclosures, there are mainly two types—one type uses fixed 1U High 19” front panel, and the other type incorporates three, or even up to five removable front panels. The latter is now becoming more popular with users, because a plug & play fiber adapter panel solution assures flexibility and ease of network deployment and MAC (moves, adds, and changes).
Splice or Pre-terminated?
Pigtail splicing and pre-terminated assemblies are the two basic way to do fiber termination. Depending on which method you choose, there are some differences in the rack mount enclosure selection. For pigtail splicing, you may need a rack mount panel with fiber splice tray, which are used for efficient management and storage of the spliced optical fibers. Splice tray is used for efficient management and storage of the spliced fiber optic cables. Fiber optic adapters are installed into the cut outs in the enclosure to accept the various fiber optic connectors. Fiber optic pigtails mate with the adapters and the fusion-spliced tails are stored on the splice tray.
But if you apply pre-terminated assemblies, the inner configuration of the rack mount panel is only the spools that are used to organize the cables. Obviously, the pre-terminated solution will help you save more installed time and labor cost.
Conclusion
In this article, you are advised to select the best fiber rack mount enclosure suitable for your own application from so many types. There are a wide range of rack mount enclosures in the market, which is good for interconnect and cross-connect in building your data centers. It’s ideal for the organization and protection of optic backbone terminations.
Originally published at www.fiber-optic-equipment.com